Laboratory equipment qualification

AI reads the instrument's URS and the manufacturer's manual and drafts the operational qualification protocol: one test per requirement, at the limits of the operating range and with the source of every criterion. The validation lead decides.

How it would work

A new liquid chromatograph, from its URS to the reviewed OQ protocol.

  • AI prepares
  • A person decides
  • Recorded in the trail
Illustrative example, not a real case

The process, documents and data in this walkthrough are fictitious. They show how the AI would work; your actual process may be different, and the system is designed around yours.

A new instrument, its URS and its manual

A new liquid chromatograph arrives at the laboratory. AI receives the URS, the manufacturer's manual and the client's protocol template.

What comes in

Instrument URS

URS-012
Accurate flow across the operating range
URS-015
Stable column temperature
URS-018
Accurate detector wavelength
URS-021
Injection volume precision of 0.3% RSD or better

Manufacturer's manual, specifications

Pump: 0.1 to 5.0 mL/min, accuracy ±1%. Oven: 10 to 80 °C, stability ±0.5 °C. Detector: accuracy ±1 nm. Injector: precision 0.5% RSD. Optional: cooled autosampler.

Client's protocol template

Objective, responsibilities, tests with their acceptance criteria, deviations and report.

Today and with AI

What changes in every protocol.

TodayWith AI

TodayEach protocol is written by hand, even when it closely resembles the one for the last instrument of the same type

With AIThe draft comes with the structure of your template and one test per requirement

TodayThe limits of each test are looked up page by page in the manufacturer's manual

With AIEach limit comes with the part of the manual it is taken from

TodayTraceability from requirement to test is built afterwards, in the matrix

With AIEach test is born with the code of the requirement it verifies: URS-012 → OQ-012

TodayWhoever writes it decides the acceptance criteria

With AIThe same: the validation lead decides, and the audit trail keeps what changed

Which AI it uses and why

It reads, connects and drafts; it doesn't approve.

Extraction
A language model reads the URS and the manual and finds the specification for each requirement, with the part of the manual it comes from.
Traceability
Each test takes the code of the requirement it verifies, as in the index of the validation documentation.
Generative
Its output is probabilistic. That is why it drafts and approves nothing.
What it doesn't do
It doesn't run the tests, decide whether a result passes or approve the protocol.

Regulatory fit

Where it sits in the draft Annex 22 and which regulations apply.

  1. CriticalIt decides something GMP: only with a static, deterministic model
  2. Non-criticalAI prepares and a person decides
  3. Outside GMPAnnex 22 doesn't apply directly

Qualification decides whether an instrument can be used in GMP, but here the model doesn't make that decision: it drafts, and the validation lead approves. The draft Annex 22 allows generative AI in non-critical uses, with qualified personnel responsible for the result. Annex 15 makes the URS the reference for the whole life cycle, so when the manual and the URS disagree, the URS prevails.

EU GMP Annex 15, 3.2
The specification of the equipment is defined in the URS, which is the point of reference throughout the validation life cycle.
Annex 15, 3.11
OQ includes tests developed from knowledge of the process and the equipment, and tests at the upper and lower operating limits or worst-case conditions.
Annex 15, 3.12
A completed OQ allows operating and cleaning procedures, operator training and preventive maintenance to be finalized.
Draft Annex 22
Generative AI only in non-critical uses, with qualified personnel responsible for the result.

See the Annex 22 guide

The seven pieces of evidence for this case

What we would deliver for this model.

01Intended use

Draft the OQ protocol of laboratory instruments from their URS, the manufacturer's manual and the client's template. It doesn't approve or assess results.

02Level of autonomy

Drafts. Nothing leaves the draft without the validation lead's approval.

03Test data

Approved protocols for similar instruments, with their URS and manuals, kept apart from the ones used to tune the instructions.

04Sources for every proposal

Each test links to its requirement and to the part of the manual its criterion comes from; anything that doesn't match is marked as pending.

05Version under change control

The model, its version, the instructions and the template.

06Recorded oversight

The proposal and what the validation lead accepted, corrected or removed.

07Monitoring in production

How many tests are corrected or removed by instrument type; if the figure rises, the system flags it.

See what the seven pieces of evidence are

Frequently asked questions

About this use case.

  • It can draft it: it looks up in the manual the specification for each URS requirement and proposes one test per requirement, with its code and its source. Under the draft Annex 22, generative AI fits non-critical uses like this one, because the validation lead approves the protocol.

  • The URS prevails: Annex 15 makes it the point of reference throughout the validation life cycle. AI marks the difference as pending and the validation lead decides the criterion.

  • No. AI doesn't run the tests or decide whether a result meets its criterion: the validation lead decides with the evidence from the execution.

Other use cases

The same way of working in other processes.

Automated visual inspection of injectables

A vision model checks every filled container, separates the defective ones and sends the ones it isn't sure about to a person.

GMPManufacturingComputer visionCritical

Deviation investigation and CAPA

AI finds the deviations in the history that describe the same problem and drafts an investigation with every source cited.

GMPQuality assuranceGenerative AINon-critical

Pharmacovigilance case intake

AI extracts the data from the report, checks whether the case is valid, proposes the MedDRA coding and looks for duplicates.

GVPPharmacovigilanceExtraction and codingOutside GMP

Process validation and ongoing verification

AI gathers batch data against the protocol's criteria, flags what drifts from the trend and drafts the report with its sources.

GMPQuality assuranceExtraction and trendsNon-critical

Tablet and blister inspection

A vision model checks every blister on the packaging line and separates incomplete ones or those with damaged tablets.

GMPManufacturingComputer visionCritical

Laboratory audit trail review

AI ranks the events of the chromatography data system's audit trail by priority, hiding none; the reviewer decides.

GMPQuality controlRules and anomaliesNon-critical

Inspection readiness

For a question from the inspector or a self inspection, AI finds the records that answer it and proposes a reply with its sources.

GMPQuality assuranceSearch with sourcesNon-critical

Material receipt

At each receipt, AI compares the delivery note, the purchase order, the supplier's labels and its certificate of analysis, and flags what doesn't match.

GMPSupply chainExtraction and comparisonNon-critical

What we need from you

To plan the system with real data.

  • The URS of the instruments you want to qualify
  • The manufacturers' manuals and specifications
  • Your protocol template and qualification procedure
  • Approved protocols for similar instruments, for testing

Does it look like your process?

Tell us how you do it today and we'll tell you whether AI adds enough to justify validating it.